Medical Implant Grade 316LVM Stainless Steel
default

Catalog Number SSATA-24398

Description

Stainless steel has a wide range of applications and is ideal for applications requiring strength and corrosion resistance. It can be customized for various medical and industrial uses.

Application

Our stainless steel products can be used in bone needles, catheters, guide wires, needles, orthodontics, orthopedic cables, skin closure staples, and other fields.

Mechanical Properties

Cold Worked % Yield Strength Ultimate Tensile Strength Elongation %
0 310 MPa [45 ksi] 627 MPa [91 ksi] 42
20 758 MPa [110 ksi] 848 MPa [123 ksi] 8
37 1000 MPa [145 ksi] 1103 MPa [160 ksi] 2.5
50 1110 MPa [161 ksi] 1213 MPa [176 ksi] 2.2
60 1172 MPa [170 ksi] 1317 MPa [191 ksi] 2.1
68 1213MPa [176 ksi] 1400 MPa [203 ksi] 2.5
75 1250 MPa [181 ksi] 1450 MPa [211 ksi] 2.6
80 1282 MPa [186 ksi] 1496 MPa [217 ksi] 2.6
84 1393 MPa [202 ksi] 1565 MPa [227 ksi] 2.6
90 1413 MPa [205 ksi] 1641 MPa [238 ksi] 2.6
93 1462 MPa [212 ksi] 1648 MPa [239 ksi] 2.6
95 1469 MPa [213 ksi] 1696 MPa [246 ksi] 2.8

Related Products

Catalog Number Product Name Order Quantity
SSATA-24395 Medical Implant Grade 302 Stainless Steel Inquiry cart
SSATA-24403 Medical Implant Grade Pure Titanium, Oxygen 0.35 Inquiry cart
SSATA-24420 Ni-Ti Tube, 1.0≤OD≤3.0 Inquiry cart
SSATA-24408 Medical Implant Grade Titanium and Titanium Alloy Plate Stock Inquiry cart
SSATA-24397 Medical Implant Grade 304V Stainless Steel Inquiry cart
SSATA-24411 Ultra-pure Ni-Ti Tube, 0.15≤OD≤0.5 Inquiry cart

GET IT!

CD BioSustainable is a well-known professional company in the industry. We provide a wide range of bio-environmental products, including bio-based materials, biomass fuels, green building materials, bio-environmental enzymes, bio-environmental microorganisms, etc. Please feel free to explore.

Our products and services are for research use only and cannot be used for any clinical purposes.

Inquiry

0
Inquiry Basket